醫(yī)用影像設(shè)備腹腔鏡攝像系統(tǒng)怎么樣?

來源:http://483177.com/ 發(fā)布時(shí)間:2021-09-30 瀏覽量:0

醫(yī)用影像設(shè)備腹腔鏡攝像系統(tǒng)怎么樣?是在保證影像質(zhì)量的前提下,考慮設(shè)備的可維護(hù)性,故障率、總體成本及后期成本等實(shí)際因素。腹腔鏡攝像系統(tǒng)是一種常見的醫(yī)用設(shè)備系統(tǒng),而腹腔鏡攝像系統(tǒng)上,在這應(yīng)用,系統(tǒng)組成,以及常見故障,對策等等都是需要進(jìn)行了解。首先也是要對于腔鏡應(yīng)用上就是無孔不入,無孔造孔,腹腔鏡就是腔鏡技術(shù)的眼睛。在這攝像系統(tǒng)上,腹腔鏡攝像系統(tǒng)的使用率也是較高。
How about the laparoscopic camera system of medical imaging equipment? On the premise of ensuring the image quality, the actual factors such as equipment maintainability, failure rate, overall cost and later cost are considered. Laparoscopic camera system is a common medical equipment system, and laparoscopic camera system needs to be understood in this application, system composition, common faults, countermeasures and so on. First of all, the application of endoscopy is all pervasive and hole making. Laparoscopy is the eye of endoscopy technology. In this camera system, the utilization rate of laparoscopic camera system is also high.
在這腹腔鏡攝像系統(tǒng)操作上,及時(shí)記錄和總結(jié)使用中、閱讀說明書和熟悉設(shè)備、配備必要的耗材和配件,簡單的事搞明白,復(fù)雜的事理清楚認(rèn)真把事情做對、用心把事情做好。 用彩條信號可基本排除信號線及視器;攝像頭、適配器、導(dǎo)光束、光源、鏡子等連接是否正常?攝像頭連線接觸不對可造成無圖像;腹腔鏡攝像系統(tǒng)怎么樣好不好?視器、光源、電視系統(tǒng)的亮度、對比度設(shè)置不當(dāng)可能使圖像無法看得清楚。
In the operation of this laparoscopic camera system, timely record and summarize the use, read the instructions and get familiar with the equipment, and equip with necessary consumables and accessories. Understand the simple things, clarify the complex things, and carefully do things right and do things well. The color bar signal can basically eliminate the signal line and camera; Is the connection of camera, adapter, guide beam, light source and mirror normal? Incorrect contact of camera wiring can cause no image; How about the laparoscopic camera system? Improper brightness and contrast settings of the camera, light source and TV system may make the image impossible to see clearly.
圖像模糊,檢查攝像頭的焦距調(diào)節(jié)是否正常,免調(diào)焦功能是否打開;檢查及擦拭攝像頭的鏡面、適配器的鏡面;檢查及擦拭光學(xué)視管的兩個(gè)表面;檢查系統(tǒng)及視器的各個(gè)信號通道,尤其注意RGB通道;用彩條信號檢查視器設(shè)置是否正常?主要是對比度、亮度的設(shè)置;氣腹機(jī)的使用可造成光學(xué)視管鏡面起霧;使用可使圖像出現(xiàn)雪花樣干擾,從而影響圖像的清晰度。
If the image is blurred, check whether the focal length adjustment of the camera is normal and whether the focus free function is turned on; Check and wipe the mirror of camera and adapter; Check and wipe the two surfaces of the optical tube; Check each signal channel of the system and the camera, especially the RGB channel; Check whether the camera setting is normal with the color bar signal? Mainly the setting of contrast and brightness; The use of pneumoperitoneum machine can cause fog on the mirror surface of optical tube; Use can make the image appear snowflake like interference, thus affecting the clarity of the image.
圖像太暗,檢查光源及其亮度設(shè)置,是否是用備用燈泡?是否使用高亮度設(shè)置?檢查調(diào)光電纜連接是否正常?檢查導(dǎo)光束與光學(xué)視管匹配是否正常?導(dǎo)光束是否有損壞(斷絲太多)?
The image is too dark. Check the light source and its brightness setting. Is it a spare bulb? Use high brightness setting? Check whether the dimmer cable connection is normal? Check whether the guide beam matches the optical tube normally? Is the guide beam damaged (too many broken wires)?
檢查OTV的亮度設(shè)置是否太低?是否打開AGC?腹腔鏡攝像系統(tǒng)怎么樣好不好?檢查視器的亮度及對比度設(shè)置是否太低?檢查電源電壓是否太低?這對燈泡的亮度有影響,尤其是鹵素?zé)?檢查纖維鏡的導(dǎo)光束是否斷絲太多?高頻電刀使用中產(chǎn)生的煙霧可使圖像亮度受影響。
Check whether the brightness setting of OTV is too low? Turn on AGC? How about the laparoscopic camera system? Check whether the brightness and contrast settings of the camera are too low? Check whether the power supply voltage is too low? This has an impact on the brightness of the bulb, especially the halogen lamp; Check whether there are too many broken wires in the guide beam of the fiberscope? The smoke generated in the use of high-frequency electric knife can affect the brightness of the image.
圖像干擾:彩條信號區(qū)別類型:彩條有干擾多半屬于電源類,彩條正常屬于系統(tǒng)干擾;檢查外界電源有無干擾,如使用大功率設(shè)備,高頻、微波設(shè)備,包括高頻電刀、電焊機(jī)、核磁共振等;攝像頭斷線可能出現(xiàn)圖像異常或沒圖像。
Image interference: color bar signal difference type: color bar interference mostly belongs to power supply, and color bar normal belongs to system interference; Check the external power supply for interference, such as using high-power equipment, high-frequency and microwave equipment, including high-frequency electric knife, electric welding machine, nuclear magnetic resonance, etc; If the camera is disconnected, there may be abnormal image or no image.
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室
  • 匠仁醫(yī)療湖南長沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區(qū)勞動(dòng)?xùn)|路820號恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室  湖南省長沙市雨花區(qū)勞動(dòng)?xùn)|路820號恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號